ELISA Analyzer

STAT FAX 4700
Catalog#

The Stat Fax 4700 is a compact, economical, stand-alone microstrip reader. Its streamlined design offers touch screen interface, superb optics, on-board curve-fitting software and built-in printer.

Features of the Stat Fax 4700 include:

  • Interactive touch-screen LCD with USB mouse option
  • Carriers in choice of styles-3 X 12 for break-apartmicrowell strips or optional 3 X 8 for solid (non-breakable) microwell strips
  • Bichromatic reading capability
  • On-board curve fitting calculations with step-by step user prompting for single & multi-point calibration curves, regression calculations, etc.
  • Easy loading on-board graphics printer
  • Memory storage for up to 120 user entered tests
  • 1 year warranty

Standard model includes four filters: 405, 450, 492, and 630 nm.
6-VIS (405, 450, 492, 545,600, 630nm) or 6-UV (340, 405, 450, 492, 545, 630 nm) available for nominal upcharge.

STAT FAX 4500
Catalog#

The Awareness Technology Stat Fax 4500 Chemistry Analyzer is a space saving, standalone system, designed to meet the demands of modern laboratories. The analyzer is equipped with brilliant bichromatic optics, on-board curve-fitting software, and an integrated printer to produce high throughput and enhance productivity.

On-board curve fitting calculations on the Stat Fax 4500 analyzer is accompanied by step-by-step user prompting to simplify and make operation easier. Equipped with an interactive touch-screen LCD with a USB mouse option, the Stat Fax analyzer also has a large non-volatile memory that stores up to 120 user-entered tests. This Awareness Technology chemistry analyzer even performs single point calibration by standard or factor, multipoint calibration and kinetic rate by standard or factor (batch or single).

Operating with IAD filters, the Stat Fax 4500 accommodates 12 mm tubes and cuvettes. The economical unit also has a read cell which is temperature controlled at 37 °C. Standard models include six filters (340 nm, 405 nm, 505 nm, 545 nm, 580 nm, and 630 nm).

STAT FAX 2600
Catalog#

The Awareness Technology Stat Fax® 2600 Microplate Washer is a fully automatic system designed for use with enzyme-linked immunosorbent assays (ELISA or EIA). This includes processing clinical diagnostic assays, multistep washing, rinsing, and soaking.

The microprocessor-controlled Stat-Fax® 2600 accepts a wide array of standard microplates and micro strip trays, and even accommodates partially filled micro strip trays. The instrument can also work with microwells having flat-, round-, or V-bottom configurations. Fully programmable, the Stat-Fax® 2600 washer provides multistep combinations of dispense, aspirate, combined aspirate/dispense, and timed soak cycles.

The Stat Fax® 2600 makes operation convenient with its user-programmable tests. The unit can store approximately 50 separate tests with up to 20 steps in its non-volatile memory. Moreover, the instrument can be programmed to automatically perform a rinse operation at a particular time of day, and can be used in the direct mode whereby wash operations are selected via the built-in keypad.

With the well depth configuration feature, the Stat Fax® 2600 gives the user freedom to assign the well depth, if preferred to the automatic well sensing option. For volumes larger than the capacity of the wells, or to reduce bubbles, a top-wash feature is included so the wash solution may be aspirated off the top as it is being dispensed. In addition to the 8-probe combination dispense/aspirate wash head, the Stat Fax® 2600 Microplate Washer is supplied with wash, rinse, and waste bottles utilizing integral electronic level sensors, and an aerosol shield.

STAT FAX 2200
Catalog#
  • Compact and easy to operate.
  • Holds two 96 well microplates for mixing and/or incubating.
  • Digitally controlled 8-speed shaker with orbital mixing from 575 to 1500 rpm.
  • Temperature adjustable from ambient to 40°C with resolution of 0.1°C.
  • Digital timer controls shaking or can be operated independently as a timer.
  • Outer tinted cover provides further insulation and protection from light.
  • NRTL and CE certified.
STAT FAX 2100
Catalog#

The Awareness Technology Stat Fax 2100 Microplate Reader is a compact, fully automatic reading unit. With its biochromatic optics, the reader is most ideal for in-vitro diagnostic use, computing the results of endpoint colorimetric assays.

A versatile unit, the Stat Fax 2100 can measure monochromatically or bichromatically. The reader also accepts many single column microstrips up to 12 wells in length, as well as break-apart wells in both flat- and round bottoms. After positioning the carrier to the desired row, the system automatically positions the strips, reads absorbances, calculates concentrations, and prints results. The integrated thermal graphics printer also allows the system to plot standard curves.

Additionally, the Stat Fax 2100 instrument offers pre-programmed modes for performing the most commonly used calculations, multiple convenience features, and user programmable memory to further facilitate testing. Each mode comes with a step-by-step prompting, reducing error and streamlining operation for the user. User-programmable memory also allows the operator to store test protocols, recall tests by number, and delete unwanted tests from a user-generated test menu.

The convenient Stat Fax 2100 reader combines automatic blanking options with the location indication of positive and negative controls. Moreover, the user can enter control acceptance criteria for automatic comparisons, and edit out discrepant duplicates with automatic reread and recalculation.

STAT FAX 1904
Catalog#

The Stat Fax 1904 Chemistry Analyzer from Awareness Technologies is a smart and reliable system featuring a step-by-step prompting and on-board graphics printer. This high performance chemistry analyzer employs a bichromatic optical system with six wavelengths, including 340 nm and pre-programmed calculation facility for both kinetic and endpoint assays.
When integrated with a Mosquito flowcell accessory, the Stat Fax 1904 allows the user to read volumes as small as 250 microliters. The 1904 is also designed with a non-volatile memory system that enables it to store up to 60 user programs.

4500brochureS1V3
Catalog#
3300brochure07
Catalog#
STAT FAX 4700
Catalog#DAR700

The Stat Fax 4700 is a compact, economical, stand-alone microstrip reader. Its streamlined design offers touch screen interface, superb optics, on-board curve-fitting software and built-in printer.

Features of the Stat Fax 4700 include:

  • Interactive touch-screen LCD with USB mouse option
  • Carriers in choice of styles-3 X 12 for break-apartmicrowell strips or optional 3 X 8 for solid (non-breakable) microwell strips
  • Bichromatic reading capability
  • On-board curve fitting calculations with step-by step user prompting for single & multi-point calibration curves, regression calculations, etc.
  • Easy loading on-board graphics printer
  • Memory storage for up to 120 user entered tests
Test Instruments
Catalog#DAR800

The Awareness Technology Stat Fax 2100 Microplate Reader is a compact, fully automatic reading unit. With its biochromatic optics, the reader is most ideal for in-vitro diagnostic use, computing the results of endpoint colorimetric assays.

A versatile unit, the Stat Fax 2100 can measure monochromatically or bichromatically. The reader also accepts many single column microstrips up to 12 wells in length, as well as break-apart wells in both flat- and round bottoms. After positioning the carrier to the desired row, the system automatically positions the strips, reads absorbances, calculates concentrations, and prints results. The integrated thermal graphics printer also allows the system to plot standard curves.

Additionally, the Stat Fax 2100 instrument offers pre-programmed modes for performing the most commonly used calculations, multiple convenience features, and user programmable memory to further facilitate testing. Each mode comes with a step-by-step prompting, reducing error and streamlining operation for the user. User-programmable memory also allows the operator to store test protocols, recall tests by number, and delete unwanted tests from a user-generated test menu.

The convenient Stat Fax 2100 reader combines automatic blanking options with the location indication of positive and negative controls. Moreover, the user can enter control acceptance criteria for automatic comparisons, and edit out discrepant duplicates with automatic reread and recalculation.